homemaker-py-sel: propose usage for all 52 corpus codes; scope was understated
Bruno's rulings settle the framing: usage is an ACCESS-REQUIREMENT class, not a room-name category. li1 "Library Corner" and br1 "Staff Room" are living rooms (same access requirements); tr1 "Treatment Room" has a bedroom's requirements (terminal, not a circulation route); la1 "Laundry Room" is utility. Ground-floor external cases (fuel stores, bins) need no class — level: 0 plus adjacency: [o] already expresses that. SCOPE CORRECTION. My "93% pure annotation, 7 entries change" estimate was mechanically true but misleading: `none` is not neutral. Nothing is stripped, so has_circulation MAY ROUTE THROUGH the room. 34 of 52 distinct corpus codes currently have no usage class and are therefore modelled as permeable corridors -- including Dental Surgery, GP Consulting, Minor Surgery, Physiotherapy, Counselling, Records, Sterilisation, six storage rooms, four offices and "Individual Room" (a resident's own room). Consequence for §38: the model OVERSTATES connectivity, since a level can be found connected through rooms that are dead ends in reality. "level N not connected" is therefore rarer than it should be, compounding §38.2 -- the objective already pays x60-85 to delete circulation, and the corridors it deletes are then not missed because store cupboards stand in for them. Adds experiments/usage_map_proposal.yaml: all 52 codes covered (47 assigned, 5 unresolved, 0 missing) -- living 10, kitchen 2, bedroom 15, toilet 7, utility 10, none 3. Nothing reads it yet; it is the review artifact and, once agreed, the migration input. Also verified and recorded (Q2): a dedicated toilet off a bedroom-class room does NOT survive scoring. has_circulation runs its bedroom loop before its toilet loop and the bedroom loop strips bedroom->toilet, so the ensuite is severed -- for real bedrooms too. Existing Urb behaviour, neither caused nor fixed by the usage key. No src changes. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01MJ84Feep79Hhm3E4zZJmnB
This commit is contained in:
parent
f476a5849e
commit
6bed7cc535
2 changed files with 123 additions and 1 deletions
File diff suppressed because one or more lines are too long
122
experiments/usage_map_proposal.yaml
Normal file
122
experiments/usage_map_proposal.yaml
Normal file
|
|
@ -0,0 +1,122 @@
|
||||||
|
# Proposed `usage:` assignments for every corpus room code (homemaker-py-sel).
|
||||||
|
#
|
||||||
|
# FOR REVIEW — nothing reads this yet. Once agreed it becomes the input to the
|
||||||
|
# migration that writes `usage:` into each `patterns.config`.
|
||||||
|
#
|
||||||
|
# Usage is an ACCESS-REQUIREMENT class, not a room-name category (Bruno's
|
||||||
|
# framing: "library corner and staff room are living rooms as they have the same
|
||||||
|
# access requirements"). What each class actually does, in `graph.has_circulation`:
|
||||||
|
#
|
||||||
|
# living keeps its MOST popular circulation neighbour; not stripped from
|
||||||
|
# other rooms, so living spaces may chain to one another.
|
||||||
|
# kitchen as living, plus `fitness.access` accepts living/circulation.
|
||||||
|
# bedroom edges to living/kitchen/bedroom/toilet are REMOVED, so it is
|
||||||
|
# reachable only from circulation or outside — a terminal private
|
||||||
|
# room, never a route.
|
||||||
|
# toilet edges to outside/living/kitchen/toilet removed.
|
||||||
|
# utility NEW. Terminal, not a route — the same requirement as `bedroom`.
|
||||||
|
# See OPEN QUESTION 1 below.
|
||||||
|
# none nothing is stripped: the room is fully permeable and the
|
||||||
|
# connectivity graph MAY ROUTE THROUGH IT. Correct only for spaces
|
||||||
|
# that genuinely are part of the circulation system.
|
||||||
|
#
|
||||||
|
# The `none` semantics are the reason this is a bigger change than it looks:
|
||||||
|
# 34 of 52 corpus codes currently get no class, so a Dental Surgery, a Records
|
||||||
|
# Room and a Utilities Closet can all serve as corridors today.
|
||||||
|
|
||||||
|
living:
|
||||||
|
cr1: Common Room with Fireplace
|
||||||
|
da1: Dining Area
|
||||||
|
en1: TV / Media Room
|
||||||
|
gy1: Exercise Room
|
||||||
|
l1: Living/Dining/Kitchen
|
||||||
|
li1: Library Corner # confirmed: same access requirements as a living room
|
||||||
|
lo1: Lounge
|
||||||
|
lr1: Common Living Room
|
||||||
|
br1: Staff Room # confirmed: same access requirements as a living room
|
||||||
|
m: Meeting Room
|
||||||
|
|
||||||
|
kitchen:
|
||||||
|
k1: Kitchen
|
||||||
|
kt1: Staff Kitchenette
|
||||||
|
|
||||||
|
bedroom: # terminal private room, entered from circulation only
|
||||||
|
b1: Master Bedroom
|
||||||
|
b2: Second Bedroom
|
||||||
|
r: Individual Room
|
||||||
|
tr1: Treatment Room # confirmed: access requirements of a bedroom
|
||||||
|
de1: Dental Surgery
|
||||||
|
gp1: GP Consulting Room
|
||||||
|
ms1: Minor Surgery Room
|
||||||
|
pt1: Physiotherapy Room
|
||||||
|
qr1: Counselling Room
|
||||||
|
py: Therapy Room
|
||||||
|
q1: Quiet Room
|
||||||
|
mo1: Manager's Office
|
||||||
|
ao1: Admin Office
|
||||||
|
em: Staff Office
|
||||||
|
of: Staff Office
|
||||||
|
|
||||||
|
toilet:
|
||||||
|
t: Bathroom
|
||||||
|
t1: Ensuite Bathroom
|
||||||
|
t2: Guest Bathroom
|
||||||
|
t3: Ground Floor WC
|
||||||
|
t9: Public WC
|
||||||
|
t10: Staff WC
|
||||||
|
tt: Upper Bathroom
|
||||||
|
|
||||||
|
utility: # terminal, never a circulation route
|
||||||
|
la1: Laundry Room # confirmed: utility, not a circulation route
|
||||||
|
ut1: Utilities Closet
|
||||||
|
me1: Mechanical/Electrical Room # "Plant / Mechanical Room" in health-centre
|
||||||
|
dp1: General Storage
|
||||||
|
st1: Ground Floor Storage
|
||||||
|
st2: First Floor Storage
|
||||||
|
ur1: Ground Floor Storage
|
||||||
|
ur2: First Floor Storage
|
||||||
|
ur3: Second Floor Storage
|
||||||
|
re1: Records Room
|
||||||
|
|
||||||
|
none: # genuinely part of the circulation system
|
||||||
|
ef1: Entrance Foyer
|
||||||
|
rc1: Reception # "Reception Office" in maple-court — see Q3
|
||||||
|
wa1: Waiting Room
|
||||||
|
|
||||||
|
# --------------------------------------------------------------------------- #
|
||||||
|
# UNRESOLVED — please rule on these
|
||||||
|
# --------------------------------------------------------------------------- #
|
||||||
|
unresolved:
|
||||||
|
ws1: Workshop Space # living (shared activity) or utility (terminal)?
|
||||||
|
zt1: Sterilisation Room # utility, or bedroom-class off a surgery?
|
||||||
|
ph1: Pharmacy / Dispensary # health-centre; bedroom-class? and see Q3
|
||||||
|
n: Neighborhood # unclear what this models at all
|
||||||
|
gh1: Greenhouse # utility, or outside-ish?
|
||||||
|
|
||||||
|
# --------------------------------------------------------------------------- #
|
||||||
|
# OPEN QUESTIONS
|
||||||
|
# --------------------------------------------------------------------------- #
|
||||||
|
#
|
||||||
|
# Q1 Does `utility` need behaviour distinct from `bedroom`? Both are "terminal,
|
||||||
|
# not a route", and the engine has no term today that would tell them apart.
|
||||||
|
# Declaring it as a distinct name that maps onto bedroom's edge-stripping
|
||||||
|
# costs nothing and makes the config read truthfully, leaving somewhere to
|
||||||
|
# hang a real difference later. The alternative is to drop it and write
|
||||||
|
# `bedroom`, which reads badly for a bin store.
|
||||||
|
#
|
||||||
|
# The "ground floor external access" cases (fuel stores, bins) do NOT need a
|
||||||
|
# class: `level: 0` plus `adjacency: [o]` already expresses that, and it is
|
||||||
|
# per-room programme data rather than an access class.
|
||||||
|
#
|
||||||
|
# Q2 A dedicated toilet off a bedroom-class room does NOT survive scoring.
|
||||||
|
# Verified: `has_circulation` runs its bedroom loop before its toilet loop,
|
||||||
|
# and the bedroom loop removes bedroom->toilet edges, so the ensuite is
|
||||||
|
# severed — for real bedrooms too, not just for treatment rooms. This is
|
||||||
|
# existing Urb behaviour that the usage key neither causes nor fixes; filed
|
||||||
|
# separately if it should change.
|
||||||
|
#
|
||||||
|
# Q3 Three codes mean different rooms in different programmes: `ph1`
|
||||||
|
# (Pharmacy/Dispensary in health-centre, Clinic Room in maple-court), `me1`
|
||||||
|
# (Mechanical/Electrical vs Plant/Mechanical), `rc1` (Reception vs Reception
|
||||||
|
# Office). Usage is declared per `patterns.config`, so they can differ — but
|
||||||
|
# it is worth confirming that is intended rather than a copy-paste drift.
|
||||||
Loading…