Ruling: corridors need daylight. Only rooms not occupied from day to day --
a cupboard, a store, a plant room -- do without it.
That overturns the classification 38.8 and 38.9 rested on. Those sections
exempted internal circulation, covered courtyards, WCs, laundries and
reception on my inference rather than any ruling. None are exempt: a
corridor is occupied all day every day, a waiting room likewise, a laundry
is a room people spend time in, a sterilisation room is a workplace.
Re-measured with the classification READ FROM THE CORPUS (a space is exempt
exactly when its own patterns.config declares crinkliness: none) instead of
inferred: 24 of 271 crinkliness fails (9%) were not defects -- not 136
(50%), not 61%. Overstated by about six times.
- uncrinkliness_circulation stays at [5/6, 1.1/3]. 38.10 called its
equality with the habitable target the purest case of an untuned value;
it is not a bug, it is the correct answer reached by default, since
corridors want daylight on the same terms as rooms.
- corpus declarations narrowed 18 -> 14. usage: utility was too coarse and
swept in Laundry Rooms and a Sterilisation Room. What remains is
storage, plant/mechanical, utilities closets and a records room.
- audit_crinkliness_truth.py rebuilt to read the classification from the
configs rather than infer it from usage:, so it cannot drift from the
ruling again.
- 38.8/38.9's inflated figures flagged in place, with 38.11 carrying the
correction.
What survives, none of it dependent on the classification: the 38.6
critique of the three modes; usage_daylight being mis-keyed; the 38.8 A/B
yardstick being wrong; and the per-space crinkliness mechanism itself.
ssz's opening measurement was right but its reading was wrong -- under this
ruling a buried leaf usually IS a defect, so scoring it zero is largely
correct. The narrowed remnant is that the score is FLAT rather than low, so
two equally-buried layouts cannot be ranked. Filed as homemaker-py-9gj; it
is a search-mechanics problem, not a calibration one.
Lint at parity (46); tests 369 passed, 2 pre-existing failures (ut5's stale
baseline and 1ue), both failing identically before this change.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MJ84Feep79Hhm3E4zZJmnB
286 lines
4.5 KiB
Text
286 lines
4.5 KiB
Text
---
|
|
# Harbor House - Programme-driven building evolution (Simplified)
|
|
# Two-story community living facility for 50+ residents
|
|
# Using anonymous interchangeable rooms to reduce complexity
|
|
|
|
# Building programme: community living spaces
|
|
spaces:
|
|
# GROUND FLOOR - Main Community Areas
|
|
cr1:
|
|
usage: living
|
|
name: Common Room with Fireplace
|
|
size:
|
|
- 80.0
|
|
- 10.0
|
|
width:
|
|
- 6.0
|
|
- 1.5
|
|
proportion:
|
|
- 2.0
|
|
- 0.5
|
|
level: 0
|
|
adjacency:
|
|
- c
|
|
- o
|
|
|
|
ef1:
|
|
usage: none
|
|
name: Entrance Foyer
|
|
size:
|
|
- 15.0
|
|
- 3.0
|
|
width:
|
|
- 3.0
|
|
- 0.5
|
|
level: 0
|
|
adjacency:
|
|
- c
|
|
# homemaker-py-1s3 (§26 path b): a foyer can double as an informal meeting
|
|
# nook (Stewart Brand "loose-fit") — declared here, validated against
|
|
# interchangeable()'s S1-S4 bounds before it's ever honoured.
|
|
co_locate:
|
|
- m
|
|
|
|
da1:
|
|
usage: living
|
|
name: Dining Area
|
|
size:
|
|
- 60.0
|
|
- 8.0
|
|
width:
|
|
- 5.0
|
|
- 1.0
|
|
proportion:
|
|
- 2.5
|
|
- 0.8
|
|
level: 0
|
|
adjacency:
|
|
- c
|
|
- k1
|
|
- o
|
|
|
|
k1:
|
|
usage: kitchen
|
|
name: Kitchen
|
|
size:
|
|
- 30.0
|
|
- 5.0
|
|
width:
|
|
- 4.0
|
|
- 1.0
|
|
level: 0
|
|
adjacency:
|
|
- da1
|
|
- c
|
|
|
|
# SLEEPING AREAS - Anonymous neighborhoods (5 total, 2 ground + 3 first)
|
|
n:
|
|
usage: bedroom
|
|
name: Neighborhood
|
|
size:
|
|
- 60.0
|
|
- 8.0
|
|
width:
|
|
- 5.0
|
|
- 1.0
|
|
proportion:
|
|
- 2.0
|
|
- 0.6
|
|
adjacency:
|
|
- c
|
|
count: 5
|
|
|
|
# GROUND FLOOR - Activity Spaces
|
|
ws1:
|
|
usage: living
|
|
name: Workshop Space
|
|
size:
|
|
- 40.0
|
|
- 6.0
|
|
width:
|
|
- 5.0
|
|
- 1.0
|
|
proportion:
|
|
- 1.8
|
|
- 0.5
|
|
level: 0
|
|
adjacency:
|
|
- c
|
|
- o
|
|
|
|
# MEETING ROOMS - Anonymous interchangeable (3 total)
|
|
m:
|
|
usage: living
|
|
name: Meeting Room
|
|
size:
|
|
- 10.0
|
|
- 2.0
|
|
width:
|
|
- 2.5
|
|
- 0.5
|
|
level: 0
|
|
adjacency:
|
|
- c
|
|
count: 3
|
|
co_locate:
|
|
- ef1
|
|
|
|
# GROUND FLOOR - Service Areas
|
|
# BATHROOMS - Ground floor (3 total)
|
|
t:
|
|
usage: toilet
|
|
name: Bathroom
|
|
size:
|
|
- 6.0
|
|
- 1.5
|
|
width:
|
|
- 2.0
|
|
- 0.5
|
|
adjacency:
|
|
- c
|
|
count: 6 # 3 ground + 3 first floor
|
|
|
|
la1:
|
|
usage: utility
|
|
name: Laundry Room
|
|
size:
|
|
- 20.0
|
|
- 4.0
|
|
width:
|
|
- 3.0
|
|
- 0.8
|
|
level: 0
|
|
adjacency:
|
|
- c
|
|
# homemaker-py-1s3: laundry and plant/M&E rooms are both "back of house"
|
|
# utility space — a common real loose-fit pairing.
|
|
co_locate:
|
|
- me1
|
|
|
|
st1:
|
|
crinkliness: none # no window needed
|
|
usage: utility
|
|
name: Ground Floor Storage
|
|
size:
|
|
- 22.0
|
|
- 4.0
|
|
width:
|
|
- 3.0
|
|
- 0.8
|
|
level: 0
|
|
adjacency:
|
|
- c
|
|
|
|
me1:
|
|
crinkliness: none # no window needed
|
|
usage: utility
|
|
name: Mechanical/Electrical Room
|
|
size:
|
|
- 25.0
|
|
- 4.0
|
|
width:
|
|
- 3.5
|
|
- 0.8
|
|
level: 0
|
|
adjacency:
|
|
- c
|
|
co_locate:
|
|
- la1
|
|
|
|
# STAFF OFFICES - Anonymous (2 total)
|
|
of:
|
|
usage: bedroom
|
|
name: Staff Office
|
|
size:
|
|
- 12.5
|
|
- 2.5
|
|
width:
|
|
- 2.5
|
|
- 0.5
|
|
level: 0
|
|
adjacency:
|
|
- c
|
|
count: 2
|
|
|
|
# FIRST FLOOR - Community Areas
|
|
li1:
|
|
usage: living
|
|
name: Library Corner
|
|
size:
|
|
- 20.0
|
|
- 4.0
|
|
width:
|
|
- 3.5
|
|
- 0.8
|
|
level: 1
|
|
adjacency:
|
|
- c
|
|
|
|
# FIRST FLOOR - Individual Rooms (10 anonymous rooms)
|
|
r:
|
|
usage: bedroom
|
|
name: Individual Room
|
|
size:
|
|
- 10.0
|
|
- 2.0
|
|
width:
|
|
- 2.5
|
|
- 0.5
|
|
level: 1
|
|
adjacency:
|
|
- c
|
|
count: 10
|
|
|
|
# FIRST FLOOR - Storage
|
|
st2:
|
|
crinkliness: none # no window needed
|
|
usage: utility
|
|
name: First Floor Storage
|
|
size:
|
|
- 18.0
|
|
- 3.5
|
|
width:
|
|
- 3.0
|
|
- 0.8
|
|
level: 1
|
|
adjacency:
|
|
- c
|
|
|
|
ut1:
|
|
crinkliness: none # no window needed
|
|
usage: utility
|
|
name: Utilities Closet
|
|
size:
|
|
- 14.0
|
|
- 3.0
|
|
width:
|
|
- 2.5
|
|
- 0.6
|
|
level: 1
|
|
adjacency:
|
|
- c
|
|
|
|
# Building constraints
|
|
storey_minimum: 2
|
|
storey_limit: 3
|
|
force_roof_garden: 0
|
|
|
|
# Circulation ratio (allow more circulation for larger building)
|
|
ratio_circulation:
|
|
- 0.08
|
|
- 0.15
|
|
|
|
# Outside space ratio (courtyard requirement)
|
|
ratio_outside:
|
|
- 0.15
|
|
- 0.10
|
|
|
|
# Staircase requirements (main + secondary)
|
|
staircase_min: 2
|
|
staircase_max: 2
|
|
|
|
# Economic parameters
|
|
value_inside: 300.0
|
|
value_circulation: 50.0
|
|
value_outside: 100.0
|
|
value_supported: 300.0
|